Ajax FireProtect 2 AC (Heat/Smoke) White Combined Heat and Smoke Detector with AC Power (White)
Mouse over the image to zoom. Double-tap and hold to zoom.
Ajax
Ajax

Ajax FireProtect 2 AC (Heat/Smoke) White Combined Heat and Smoke Detector with AC Power (White)

Product Code: ITM004073
UPC: AJAX FIREPROTECT 2 AC (HEAT/SMOKE) WHITE - 60832.175.WH1
Login to View Price
Online Availability
Quantity Available: 0
Availability: Out of stock
Communication
Jeweller communication technology
Proprietary wireless communication technology to transmit commands, alarms, and events.

Key features:
Two-way communication.
Advanced anti-sabotage.
Block encryption featuring a dynamic key.
Instant notifications.
Remote configuration in the Ajax apps.
Frequency bands
866.0 €“ 866.5 MHz
868.0 €“ 868.6 MHz
868.7 €“ 869.2 MHz
905.0 €“ 926.5 MHz
915.85 €“ 926.5 MHz
921.0 €“ 922.0 MHz
Maximum effective radiated power (ERP)
up to 20 mW
Radio signal modulation
GFSK
Radio communication range
up to 1,700 m
Encrypted communication
All stored and transmitted data are protected by block encryption featuring a dynamic key.
Frequency hopping
Radio communication uses frequency hopping to prevent interception and jamming.
Sensitive elements
Sensitive elements

smoke sensor
heat sensor
CO (carbon monoxide) sensor
Smoke detection
Sensitive element
double-spectrum optical sensor
Detects smoke by the size of particles in the air.
Protection from false alarms
Does not react to water vapor.
Patented smoke chamber
Protects the smoke sensor from dust, dirt, and insects
Dangerous temperature detection
Sensitive element
according to the requirements for Class A1R heat detectors
Requirements of EN 54-5 and BS 5446-2 standards.
High temperature alarm
at temperatures above 64°C
Temperature spike alarm
when the temperature rises by more than 10°C in 1 minute or less
Additional features
Built-in siren
volume 85 dB at a distance of 3 meters
Sound notification of alarms. Remains active until the reason for triggering is eliminated or until the user manually disables the notification.
Interconnected fire detectors alarms

via primary interconnection
If one of the fire detectors in the system detects a threat, it sends an alarm to the hub. Within 20 seconds, the hub initiates an interconnected alarm and sends data to Ajax apps.

via fallback interconnection
At the same time with notifying the hub, the initiating detector sends an alarm directly to other detectors. All connected detectors activate the buzzer within a minute. It will work even in the worst-case scenario of losing connection with the hub.
LED indication
green is a power indication
An LED indicator on the device enclosure lights continuously when powered by an external power source. If the device draws power from the backup battery, the LED indicator lights up once every 56 seconds. This indication complies with the requirements stipulated in EN 14604 and EN 50291 standards.

yellow is a malfunction indication
An LED indicator on the device enclosure lights up to signal detected malfunctions. This can occur in instances such as battery depletion, smoke chamber contamination, or reaching the end of the service life.

red is a fire alarm indication

An LED indicator on the device enclosure lights up when the detector registers a fire alarm.
Button on the front panel of the detector
In normal mode, when pressed, it starts the smoke chamber test. In the event of an alarm or malfunction, the pressing turns off the detector sound notification.
External power supply
110€“240 V~, 50/60 Hz
The phase and neutral cables from the external power supply should be connected to the WAGO terminals on SmartBracket mounting panel. To remove the detector from SmartBracket, there is no need to disconnect the power cables.
Recommendations
Recommendations
The device is designed for indoor installation only.
SmartBracket mounting panel allows adjusting the position of the detector even after installation.
Sabotage protection
Tamper alarm
Notifications on attempts to detach the detector from the surface or remove it from the mounting panel.
Protection against spoofing
device authentication
Communication loss detection
within 15 minutes
The time required to detect a communication loss depends on the settings for the number of undelivered data packages (specified in the Jeweller or Jeweller/Fibra settings).
Power supply
Main
110€“240 V~, 50/60 Hz
Backup
1 non-replaceable lithium battery CR-2/3AZ
Enclosure
Dimensions
122 x 122 x 54 mm
Weight
318 g
Operating temperature range
from 0°Ð¡ to +50°Ð¡
Operating humidity
up to 80%
Colours
Black or white
Complete set
FireProtect 2 AC (Heat/Smoke) Jeweller
SmartBracket mounting panel
WAGO 221 3-conductor terminal €” 2 pcs.
(pre-installed in SmartBracket)
Installation kit
Quick start guide
Our website requires cookies to enhance your online browsing experience. For example, these cookies allow you to save products in your shopping cart, even when you’re not logged into your account. These cookies are crucial for ensuring the website functions correctly.